Thalpeon
For homes across Europe · heat pumps & air conditioning

Size the heat pump and the air conditioning from the house, not a rule of thumb

Thalpeon works out a home's heat loss and cooling load room by room, with European standards and the hourly weather of its own location. It then gives the size of unit to buy, what it will cost to run over a year, and which upgrades pay back.

EN 12831-1 heating load EN ISO 52016-1 cooling & yearly energy Local weather for any site in Europe
Thalpeon results page: heat pump size, air-conditioning size and the expected yearly running cost of a two-storey house

What you get for each house

Every figure comes from the building you describe: its walls, roof, floors and windows, which way they face, how airtight it is, and how it is used.

Heating

Heat pump size

The design heat load by EN 12831-1, room by room: walls, roof, ground floor, thermal bridges, ventilation and air leakage. The heat pump size includes a 20 % margin.

Cooling

Air-conditioning size

The cooling load hour by hour on a hot design day of your climate zone, with sun on each façade, people, appliances and humidity. Room by room, with a 25 % margin for the A/C.

Running cost

The year, hour by hour

Heating, cooling and hot water through a typical year of local weather, giving the expected kWh and the yearly bill for your heating and cooling system, fuel and electricity prices.

Rating

Indicative energy class

For EU countries whose national method is built in, an estimate of the class an Energy Performance Certificate would give, with more countries being added.

Fabric

U-value calculator

Walls, columns, flat and pitched roofs, ground floors and windows, layer by layer by EN ISO 6946, EN ISO 13370 and EN ISO 10077-1, from a library of building materials.

Upgrades

Improvement scenarios

Try insulation, new windows, a different heat pump or PV panels, and see the new loads, the yearly saving and the payback before you spend anything.

From the architect's drawing to the loads

Open the floor plans as PDF and trace each room. Thalpeon measures the areas, the external walls, every window and door and which way it faces, and builds the house in 3D.

  • Levels lined up from two common points on the drawings
  • Thermostat zones with their own set-points and hours
  • The heat-loss colours shown on the building, side by side
  • A calculation report to print or save as PDF
Rooms of a two-storey house traced on its floor plan in Thalpeon, with their areas, windows and doors

Three levels of detail

Start with a few plain questions, and add detail where it changes the answer.

~3 min

Basic

Size, age, insulation and comfort, answered with pictures. For a first idea of the heat pump and A/C a home needs.

~10 min

Advanced

Rooms with their areas and walls, windows by side, U-values from the layers. Heating and cooling load for every room.

~30 min

Expert

Traced drawings, 3D view, thermostat zones, heating and cooling systems, fuel prices and improvement scenarios with payback.

Built on published standards

The methods are the ones an engineer would recognise, and each assumption is written down.

Heating design load
EN 12831-1:2017: transmission, ground (EN ISO 13370), thermal bridges, ventilation and infiltration, room by room.
Cooling design load
EN ISO 52016-1 hourly model on ISO 15927-2 design days worked out from the local weather station's records; sensible and latent.
Yearly energy
EN ISO 52016-1 through a typical year of hourly weather (PVGIS and NOAA stations), sun on each façade by ISO 52010-1.
U-values
EN ISO 6946 for walls and roofs, EN ISO 13370 for ground floors, EN ISO 10077-1 for windows, layer by layer.
Energy class (indicative)
The selected country's own certificate method, where it is built in.
Checked
Against the standard's own BESTEST test cases, and side by side with EnergyPlus (design-day cooling within 1 %).

Indicative, not a certificate. Energy Performance Certificates are issued by registered assessors under each country's own rules. Thalpeon's results, including its energy class, are estimates for design and comparison.

Request access

Thalpeon is opening to engineers, installers and homeowners in stages. Leave your details and we'll let you know when your account is ready.

We use your name and email only to reply to you, and delete them within 12 months. Privacy notice

Questions

How big a heat pump does my house need?

It depends on the house's heat loss on a cold design day: insulation, windows, air leakage, size, and where it is. Thalpeon works this out by EN 12831-1 and adds a 20 % margin. Rules of thumb such as 100 W/m² often give a much bigger unit than a well-insulated house needs, and an oversized heat pump costs more to buy and runs less efficiently. More in the guide How much heating does my home need?

Is the energy class an official certificate?

No. Only a registered assessor can issue an Energy Performance Certificate. Where Thalpeon has a country's published method built in, it follows it to give an indicative class, useful for design and for comparing upgrades. Elsewhere it gives the heating, cooling and running-cost results.

Which areas does it cover?

The EU, plus Iceland, Liechtenstein, Norway, Switzerland and the UK. Pick the building on a map: its design temperatures and a typical year of hourly weather come from the nearest weather stations (NOAA) and the EU's PVGIS solar data for that spot.

Do I need to install anything?

No. Thalpeon runs in the browser on a computer, tablet or phone. Your projects are saved to your account, stored in the EU, and can be exported at any time.